CURRICULUM VITAE
Abhishek S Jadhav
REVIT MEP Engineer [email protected]
Mobile no: 9741465447
Carrier objective
I like to work in an organisation which is competitive and challenging and enjoy career. I want
to use my education to carry out my task with efficiency, professionalism and cost effectiveness.
Educational qualification
Qualification University Year of passing Score (%)
BE(Mechanical) Visvesvaraya Technological
University, Belgaum 2016 66
PUC(Science) Pre University Board, Bangalore 2012 74
SSLC Karnataka Secondary Education
Examination Board ,Bangalore 2010 68
Academic project
Experimental investigation of velocity distribution over the curved surface due to jet
impingement.
It is observed that velocity at the surface is zero due to the viscous force of the air
molecules towards the surface, which gradually increases along radial distance and
gradual decrease of velocity for further radial distance. this is because; as the wall jet
comes in contact with atmospheric air loses its momentum with the atmospheric air. It is
found that velocity is maximum at the point of impingement and decrease gradually
along the circumferential locations.
About internship
Undergone the field work in carriage repair workshop, south western raliway, hubli
Undergone the industrial training in SPARKLINE EQUIPMENT PVT LTD, PUNE.
Achievement
Represented KLS’s VDRIT, HALIYAL and secured the distinction as third place in
VTU NETBALL (M) INTER COLLEGIATE INTER ZONE TOURNAMENT.
ABHISHEK JADHAV MECHANICAL ENGINEERING [email protected] 9741465447
Professional experience
BIM MEP Design intern at Desapex Engineering Consultants LLP.
Software skills
AUTODESK REVIT - 14, MS office – 10
Key professional skills
Linking the CAD FILE to REVIT
Creating space and Space schedules
Creating ZONES and updating the cooling outdoor air information as per ASHARE 62.1
Performing HEAT LOAD REPORT
Designing HVAC SYSTEM
Duct design as per guideline of ASHRAE
Performing the PRESSURE DRO
Selecting the air conditioning apparatus(AHU, FCU)
Selecting the chillers and cooling tower
Designing TOILET VENTILATION
Selecting the exhaust fan
Designing the plumbing system water supply and drainage system as per NBC part 9
Designing the FIRE FIGHTING SYSTEM as per NBC part 4
Running INTERFERENCE CHECK and exporting the interference report
Preparing the BILL OF QUANTITIES(BOQ)
Exporting the REVIT FILE to CAD
Personal detail
Name Abhishek Jadhav
Gender Male
Father name Sambhajirao Jadhav
Date of birth 26 – 12 – 1994
Nationality Indian
Language known English,kannada,hindi and Marathi
Declaration
I hereby declare that the details given above are true as per my knowledge and belief.
YOUR FAITHFUL
Abhishek Jadhav
ABHISHEK JADHAV MECHANICAL ENGINEERING [email protected] 9741465447
4 REVIT MEP AND HVAC DESIGN
Project Details
Building type : IT Office space
Location : Bengaluru, India
No. of floor : Ground floor + 12 floors
Area of building : 3,77,060 SF
Occupancies : 6,840
HVAC Summary
Total cooling load : 680 TR
Air Quantity : 2,41,553 CFM
Air distribution system : VAV single duct system
Chilled water system : Central chilled water system
Pumping method :Primary variable system
ABHISHEK JADHAV MECHANICAL ENGINEERING [email protected] 9741465447
5 REVIT MEP AND HVAC DESIGN
Heating And Cooling Load
Estimation
Details of the building such as
Building type
Location
Ground plane
Project phase
Building service, etc are updated
Heat Load Report
Calculated results for each floor
Peak cooling total load (tons) = 52
Peak sensible load (tons) =37
Peak latent load (tons) =15
Peak cooling air flow (cfm) =18,581
ABHISHEK JADHAV MECHANICAL ENGINEERING [email protected] 9741465447
6 REVIT MEP AND HVAC DESIGN
Air Distribution System
Air Terminal
Ceiling mounted diffusers were
selected for supply air terminals
Grills were selected for return
air terminals.
Duct design
Duct sizing done based on equal
friction method
Volume control damper were
introduced at each branch for
balancing air
Fire dampers were placed at wall opening
Critical Path of Pressure Drop
Pressure drop report exported in HTML format
From critical path, static pressure and flow rate were
found.
This static pressure is used in selecting fan for AHUs.
ABHISHEK JADHAV MECHANICAL ENGINEERING [email protected] 9741465447
7 REVIT MEP AND HVAC DESIGN
Air Handing Unit
AHU Type: Draw through
Cooling apparatus: Chilled water coil.
Circulating fan were selected for static pressure and air flow found
from critical path
Chiller
Water Cooled Screw Chiller
Type of condenser : Water cooled type.
Type of compressor : screw type.
Inlet water temperature : 59 0F.
Outlet water temperature : 47 0F.
No. Of chillier : 2
Capacity : 300(ton)each
Cooling tower
Mechanical induced draft cooling tower - Counter flow type
ABHISHEK JADHAV MECHANICAL ENGINEER [email protected] 9741465447
8 REVIT MEP AND HVAC DESIGN
Toilet Ventilation
FLOOR WISE EXHAUST TERRACE EXHAUST
From each floor 2082 CFM of air quantity was exhausted
980 CFM from one toilet is exhausted floor wise and 1100CFM from another toilet is exhausted through terrace
For floor wise exhaust centrifugal inline fan were used
For terrace exhaust SISW fan were used
ABHISHEK JADHAV MECHANICAL ENGINEER [email protected] 9741465447
9 REVIT MEP AND HVAC DESIGN
Plumbing
Plumbing pipe sizing done as per NBC PART – 9 Plumbing
services
For office water requirement – 45 litters per head per day.
For visitors water requirement – 15 litters per head per day
Domestic cold water supply
Water supply system: Domestic cold water.
Water closet - 2.20 FU
Lavatory - 0.50FU
Urinals - 10 FU
Over head tank distribution
Drainage system
DRANIAGE SYSTEM: Two pipe system
Floor drain and lavatory were connected to grey
water pipe
Water closet and urinals were connected to black
water pipe
Water closet - 4 FU
Lavatory - 1 FU
ABHISHEK JADHAV MECHANICAL ENGINEER [email protected] 9741465447
10 REVIT MEP AND HVAC DESIGN
Urinals - 4 FU
Floor drain – 1 FU
Slope maintained - 1:100
Fire Fighting System
As per National Building Code, for the type of
building and floor space the requirement type of fire
protection was taken into consideration.
Fire sprinkler and alarm was located to cover all
area to respond for fire hazard.
Building design as per NBC PART 4
Sprinkler used: Pendent Type (15 mm).
Coverage : 3000 mm
Pipe sizing done according to NFPA 13 (National Fire
Protection Authority)
ABHISHEK JADHAV MECHANICAL ENGINEER [email protected] 9741465447
11 REVIT MEP AND HVAC DESIGN
Electrical
Lighting fixture, conduit and cable trays were placed
For workstation Pendant lighting fixture were placed
For cabin and discussion room ceiling light flat round
were placed
And for toilets round down light were placed
Clash Detection
Interference check made between current project –
current project and current project - linked project.
Interference report were generated to resolve the
clashes between system
ABHISHEK JADHAV MECHANICAL ENGINEER [email protected] 9741465447
12 REVIT MEP AND HVAC DESIGN
Clashes between different systems were inspected
and resolved by co- ordination by either rerouting or
changing its offset
Zero clash model is achieved
BILL OF QUANTITIES (BOQ) are generated
Air terminal
Duct
Pipe
Sprinkler
Duct accessory
Pipe accessory
Duct fitting
Pipe fitting
ABHISHEK JADHAV MECHANICAL ENGINEER [email protected] 9741465447
13 REVIT MEP AND HVAC DESIGN
DRAWING SHEET
ABHISHEK JADHAV MECHANICAL ENGINEER [email protected] 9741465447
15 REVIT MEP AND HVAC DESIGN