8/6/2019 ROHIT VIJAY
1/22
SUBMITTED BY: GUIDED BY:
ROHIT VIJAY Mrs. SUMAN PURI
(B.TECH, VII SEMESTER) Head of the department
FINAL YEAR Department of
Electrical Engg.
-
8/6/2019 ROHIT VIJAY
2/22
The KOTA SUPER THERMEL POWER STATION isideally located on the left bank of Chambal River at theupstream of KOTA BARRAGE
Total Generation Capacity 1240 MW
Stage I (Two units each of 110 MW)Stage II (Two units each of 210 MW)
Stage III (One unit of 210 MW)Stage IV (One unit of 195 MW)Stage V (One unit of 195 MW)
-
8/6/2019 ROHIT VIJAY
3/22
Water availabilityin large amount.
Concentration of load in region.
Continue power supply.
Coal availability.
Central grid location.
-
8/6/2019 ROHIT VIJAY
4/22
-
8/6/2019 ROHIT VIJAY
5/22
Generator
Transformer
Motor
Coal Handling PlantAsh Handling Plant
Water Treatment Plant
Switch Gear
Switch YardSwitch Yard
ProtectionProtection
Auxiliary SupplyAuxiliary Supply
Control RoomControl Room
TurbineTurbine
BoilerBoiler
ElectroElectro--StaticStatic
PrecipitatorPrecipitator
-
8/6/2019 ROHIT VIJAY
6/22
-
8/6/2019 ROHIT VIJAY
7/22
-
8/6/2019 ROHIT VIJAY
8/22
-
8/6/2019 ROHIT VIJAY
9/22
Switchgear Employed for the protection of Inductionmotor.
Generally two basic protectionviz short circuitprotection and overload protection are provided foreach motor.
The Switchgear used for protection includes
contractors with H.R.C. fuse and thermal overloadrelays along with CB.
-
8/6/2019 ROHIT VIJAY
10/22
1) PHASE TO PHASE FAULT
2) EARTH FAULT
3) INTER-TURN FAULT
1) CONDUCTOR TO EARTH FAULT
2) BEARING FAILURE
3) FAULT IN STARTER & ASSOCIATED CIRCUITS
-
8/6/2019 ROHIT VIJAY
11/22
y OVERLOADING
y STALLINGy UNBALANCE SUPPLY VOLTAGES
y SINGLE PHASING
y
UNDER VOLTAGEy REVERSE PHASE
-
8/6/2019 ROHIT VIJAY
12/22
Earth leakage Core balance CT and
Relay
Earth fault Earth Return CT
Unbalance 3Phase CT and Relay
Overload Thermal overload relay
Over current IDMT Relay
Stalling Motor protection relay
Short circuit Instantaneous relays
Fuses
Differential Basically for earth fault
within a particular zone.
CT on both sides
Under Voltage UV Relay
Over Voltage Over Voltage Relay
Unbalance Single Phase Preventers
Single Phasing
-
8/6/2019 ROHIT VIJAY
13/22
-
8/6/2019 ROHIT VIJAY
14/22
y It is used below 1000v.
y Three phase supplyis given to the motor throughvarious elementssuch as fuse, Switch,contactor &thermal overload relay.
y
Magnetic contactor
starter con
sist of a
set of
start an
dstop push buttons with associated contacts.
-
8/6/2019 ROHIT VIJAY
15/22
-
8/6/2019 ROHIT VIJAY
16/22
-
8/6/2019 ROHIT VIJAY
17/22
-
8/6/2019 ROHIT VIJAY
18/22
This method to provide earth fault protection is calledcore balance type protection.
It is also calledzero sequence current transformer.
It is preferred the system with neutral earthed wiresystem.
-
8/6/2019 ROHIT VIJAY
19/22
-
8/6/2019 ROHIT VIJAY
20/22
It is based on the electromagnetic principle.
Rev
erse pha
se protect
ion mu
st be pro
vide
dinElevators , cranes, trams etc.