क्ा आप गर्मी औ सीलन स / प /शान ह...
TRANSCRIPT
Do you have trouble with heat & humid ???
क्या आप गर्मी और सीलन से परेशान है ???
StarShield Cool Coat - Product Detail
Presenting
2
An unprotected building roof is directly exposed to extreme weather condition like Sun’s Heat & Rain. Repeated weather cycles deteriorates the condition of roof, causing cracks on it.
Due to excessive heat, the A/C’s & Coolers has to run
for a longer time to bring down the temperature.
This results in increase power consumption.
During monsoon, the water tends to enter through the
cracks formed due to heat. This rain water absorption
causes multiple damages to the buildings.
In industries also, the working environment gets very
hot during summers & effects the productivity of the
labors. Similarly, during summers, the water in storage
tanks & pipe lines gets very hot.
3
Above Picture shows that a house with Star cool shield paintis smiling in peak summers whereas the house with normalpaint is looking tense due to extreme heat.
Star Cool Shield is the revolutionary field proven Eco friendly heat reflective & insulating cool coating.
Star Cool shield has been certified as Highest in Solar Reflectance Index, SRI Value -130, tested by NABL Certified lab as per ASTM/LEEDS per standards for green buildings.
STAR COOL SHIELD is designed to reflects sunlight to a greater extent and prevents the roofing materials from getting heated up, even in peak summer afternoons. keeping the interior cool and comfortable.
4
SRI Value130
5
StarShield Technologies feels proud to be an IGBC member (Indian Green BuildingCouncil), member of LEED, USGBC (United States Green Building Council) & Certified byGRIHA Council (Green Rating for Integrated Habitat Assessment) & also an ISO9001:2015 Certified Company
StarShield Cool Coat is a water based high solids, flexible, 100% acrylic chemical insulating coating which is highly reflective
6
Highest SRI (130)
No Primer Required
Non Flammable
Thermal Barrier
Liquid Resistant
Heat Insulating
99% Thermal Emmiltance
Anti Fungus
Scratch Resistance
There are many benefits of StarShield Cool Coat, some are:
7
Bridge Cracks
Power Saving up
to 30%
Cools up to
22Degrees
Control Leakage
8
0
10
20
30
40
50
60
70
80
Ambient Temp.
StarShield Coated
Uncoated roof
Thermal Test
9
Solar Reflective Heat Resistive
Water Resistant Maximum Coverage
SRI -130 (Highest)
10
Eco Friendly
Low VOC
Saves Energy
Anti Fungus
Non Toxic
Star Cool Shield improves our lives by improving the environment we live in by using no harshful chemicals in the coating and complying ASTM/LEEDS standards for green buildings.
Due to excessive heat, the A/C’s & Coolers has to run for a longer time to bring down the temperature. This results in increase power consumption.
By applying StarShield Cool coat on the roof & exterior, UV Rays & infrared rays gets rejected continuously. Which cools down surface temp. in excess of 22 Degree Celsius.
and with internal coating of StarShield, makes the walls and roofs more insulated.
Thus, makes the walls less absorbable & helps us in exceeding
Energy Star & Cool Roof Council Guidelines.
11
12
ROOF WITHOUT STARSHIELD COAT
U Value : 0.52Considered 6" Concrete slab with 1" Brick & Plaster on one sideAir Conditioning Tonnage : 11.34 TRPower Consumption : 15.87 KwhTonnage for 12 Hours of operation / day : 136.08 TRPower for 12 Hours of Operation /day : 190.51 UnitsConsidering INR 7.00 / units : Rs 1333.57
ROOF WITH STARSHIELD COAT
U Value : 0.25
Considered 6" Concrete slab with 1" Brick & Plaster on one side with STARSHIELD on TerraceAir Conditioning Tonnage : 9.46 TRPower Consumption : 13.24 KwhTonnage for 12 Hours of operation / day : 113.52 TRPower for 12 Hours of Operation /day : 158.88 UnitsConsidering INR 7.00 / units : Rs 1112.16
13
Investment for STARSHIELD COOL COAT : Rs 17000.00Capacity of the AC Saved /Hour due to STARSHIELD : 1.88 TRSavings in Power /Hour due to STARSHIELD COAT : 2.63 KwhSavings in Tonnage for 12 Hours of operation / day is : 22.56 TRSavings in Power for 12 Hours of Operation /day : 31.63 UnitsSavings / Day - Considering INR 7.00 / units : Rs 221.41Total area : 23,199Total Tonnage : 135 TR for 23,199 sq.ftTonnage for 12 hours of operation/ day : 1,620 RTPower for 12 Hours of Operation /day : 2,267.3 Kwh
Investment for STARSHIELD COOL COATSavings in Tonnage for 12 Hours of operation / day : 324 TRSavings in Power for 12 Hours of Operation /day : 453.46 UnitsSavings / Day - Considering INR 7.00 / units : 3,174.224Pay Back Period for 23,119 Sq.ft : 135.2 days for Rs 29181.50
% of power Saving is 20%Note: Exact savings can be given only after getting all the building
& HVAC parameters
14
In summer, it becomes nearly impossible for devotees to walk bare footed in Temples& other religious places, So you can make a corridor on the floor with Star Cool Shieldon the floors & cools the surface & makes it comfortable to walk.
1. Scrub & Clean the surface to be coated thoroughly with metal/ plastic brush to be freed from black color, fungus, loose masonry, dirt & dust.
2. Wash the scrubbed surface with plenty of water to remove dust & dirt.
3. Allow the surface to get dry.
4. Mix the StarShield Cool Activator in it. (optional)
5. Dilute the StarShield Cool Coat with 25% water.
6. Stir the coat well with stirrer before use.
7. Apply the 1st Coat with brush/roller/spray.
8. Allow the coating to get dry for 4 hrs.
9. Apply Final Coat.
10. Allow it to get dry for 48 hrs.
15
Note: a) Apply External Primer for Painted & Polished Surfaces.b) Its easy to apply & any helper or painter can do the job easily.
StarShield Cool Coat can be applied on walls & all kinds of roofs like RCC/Tile/Asbestos/GI Roof, Kota Stone, water Tanks & any other exterior and interior surface.
16
Houses / Complex Factories/Industries Air Conditioned Buildings
Hospitals/Clinics
Sintex Water Tanks / Water Pipelines
Warehouses / Cold Storage
Schools / Colleges Office / Commercial Buildings
Shopping Malls Green Buildings Pre FabricatedCabins
Animal Sheds
Solar Reflectance Index : 130 as per ASTM E 1980
Solids by Weight : 70% (+ 2%)
Solids by Volume : 50% (+ 2%)
Thermal Emmiltance : 0.99 as per ASTM C 1371
Solar Reflectance : 1.00 as per ASTM C 1549
Resistance to Heat @125 : No change as per IS: 101 (P-7, Sec-3) 1990
Volatile Organic Compound (VOC) : 5.2 gm/ltr as per ASTM D 2369
Tensile Strength : 0.878Mpa
Temperature Limits : -18 degree to 80 degree Celsius
Elongation : 200% (+20)@24 degree Celsius
Hardness : 70 to 80 Shore A
Permeance : 3.2 Perms @ 17 mils
Permeability : 0.05 per inch
Crack Bridging : Bridges Gap up to 1.6 mm
Radiation Value : Infrared@90%
UV@89%
17
Fire Resistance : Class A, Non- Combustible
Explosively : Non-Explosive
Heat Reduction : 8 degree to 22 degree Celsius
Reduction In Chloride ion : 90%
Coating Thickness : 150-200 microns
Consistency : Smooth & Uniform
Scratch Hardness : No Scratch as per IS 101 (P-5/ Sec-2) 1988
Cross Cut adhesion : No Peeling or removal of the film
Resistance to Liquid : as per IS 101 (P-5/ Sec-2) 1990
Resistance to Water : No Remove Coating
Resistance to Sodium Nitrate : No Remove Coating
Resistance to Ammonia Solution : No Remove Coating
Resistance to Soap Solution : No Remove Coating
Resistance to Sodium Hydroxide : No Remove Coating
18
19Note: Data of Other Chemical Coatings have been taken from their websites, brochures & technical data sheets
DESCRIPTION STARSHIELD Coating-1 Coating-2 Coating-3 Coating-4
SRI Value 130 122 112 104 83.8Catalyst Activator YES NO NO NO NO
RESISTANCE TO HEAT YES NO YES NO NO
RESISTANCE TO 5 Liquids YES NO NO YES NO
Thermal Emmiltance 0.99 0.939 0.93 0.89 N.A.
Solar Reflectance 1.00 0.874 0.838 0.84 N.A.
Solid Content 65+% >60% 65% >50% 63%
Fibre Reinforcement 228.00% 200% 228% 150% 100%
ApplicationBOTH EXTERNAL &
INTERNALONLY EXTERNAL ONLY EXTERNAL ONLY EXTERNAL ONLY EXTERNAL
Contains Insulative..Material
YES YES NO NO NO
Eco Friendly YES YES YES YES YES
Toxic NO NO YES NO NO
Primer Required NO NO No YES YES
VOC 5.2 gm/ltr LOW VOC LOW VOC LOW VOC LOW VOC
Coverage26-30 Sq.ft. in Double Coat
25 Sq.ft. in Double Coat
25 sq.ft in Double Coat
22 sq.ft Double Coat 30 sq.ft in Single Coat
Life Expectancy 5-7 years 5-7 years 5 years 3-5 years 3 years
Cost per 20 Ltrs 7790/- 7800/- 6630/- 7000/- 8750/-
Cost per Sq.ft in Rs. 13.9/- 15.6/- 13.26/- 15.9/- 29.16/-
Life: Expected Life Of Star Cool Shield varies From 5-7 Years
Note: Price are exclusive of Tax & Freight, Management reserves the right to change prices anytime
Description of Goods & Quantity
Coverage Price in Rs
1 Ltr – (SRI 130)StarShield CanHeat Reflective and Insulating Coating
26-30 Sq.ft..(Double Coat)
Rs. 480/-
4 Ltrs – (SRI 130)StarShield bucketHeat Reflective and Insulating Coating
104-120 Sq.ft..(Double Coat)
Rs. 1705/-
10 Ltrs – (SRI 130)StarShield bucketHeat Reflective and Insulating Coating
260-300 Sq.ft..(Double Coat)
Rs. 3800/-
20 Ltrs – (SRI 130)StarShield bucketHeat Reflective and Insulating Coating
520-600 Sq.ft..(Double Coat)
Rs. 7419/-
Address: R-1/88, R.D.C. Above ICICI Bank,Raj Nagar Ghaziabad, UP-201001, INDIA
Customer Helpline: +91 011 3008 6111Partner Helpline : +91 011 3008 6222
Email: [email protected]: www.starshield.in
21