COLEMAN MODEL 101 UV SPECTROPHOTOMETER Range down to 220 ωμ · Bandpass approx. ΊΟ η%μ · Line operated -* a ?fo..=-.-j», !K , Mûmm. 909S-P10. ,,^ '4tt modified to provide increased stability for continuous monitoring; adjustable output for use with a recorder; and connections for digital readout or printout SPECTROPHOTOMETER, Coleman Model 101- 002, UV range 220 to 37S m> Single beam, diffraction grating type, a.c. line operated, with fixed bandpass of approximately 10 ιημ. With deu- terium lamp and power supply housed separately. Usable in ultraviolet range down to 220 ιημ. Dimensions: 16 inches long X 11 inches deep X 63^2 inches high. Simplicity of operation makes this instrument suitable for routine general analysis and for educational use. Wide Range Phototube. Single tube, with detectors of antimony-cesium and silver-cesium, covers range 220 to 900 ταμ. Energy Recording. Terminal jack is provided with output adjustable 0 to 200 mv for use with a recorder. Linear Wavelength Control. Drum scale 200 to 970 ταμ in 1.8 mm spaced divisions corresponding to 5 ταμ. Meter Scale. Mirrored 5H-i nc h scale, graduated 0 to 110% transmittance and —0.04 to 2.0 absorbance. Performance Specifications Bandpass. Approximately 10 ταμ throughout range. Photometric Accuracy. Transmittance ±0.5%; absorb- ance ±0.006 at 0.4. Photometric Reproducibility. Transmittance 0.2%. Wavelength Accuracy. Better than +2.5 ιημ throughout range. Slits. Fixed; entrance 0.3 mm wide; exit 1.2 mm wide. Stray Light. Less than 0.5% Τ at 340 ταμ. Celi Path. Light path 5, 10 or 20 mm; 4~place Holder. Def ailed bulletins 9095-F10. UV Spectrophotometer, Thomas modified Coleman 101-002, range 220 to 375 ιημ, as described. Complete with deuterium lamp and power supply, 4- place cell holder, set of 2 fused silica cells with eovers, etc. For 115 volts, 60 eye. a.c 1,475.00 NOTE—Model 101 is also available with tungsten lamp and power supply for use in the range 340 to 900 mn. Information on request. ^ ί DIGITAL CONVERTER, Thomas. Prints absorb- ance, transmittance or concentration 4-digiO readings on tape with 4-digit sample identifica- tion numbers in adjacent column. Operates from output of various Thomas Readouts. im&M#d Ύ sent upon request. ARTHUR H. THOMAS COMPANY Scientific Apparatus and Reagents VINE STREET AT 3RD · P.O. BOX 7 7 9 « PHIUAOELPHIA 5, PA., U.S.A. Circle No. S3 an Readers' Service Card Π 6 A » ANALYTICAL CHEMISTRY

Upload: dinhxuyen

Post on 07-Feb-2017

214 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: ARTHUR H. THOMAS COMPANY

COLEMAN MODEL 101 UV SPECTROPHOTOMETER Range down to 220 ωμ · Bandpass approx. ΊΟ η%μ · Line operated

-*a?fo..=-.-j», !K,

Mûmm. 909S-P10.

, , ^

' 4 t t

m o d i f i e d to p r o v i d e i n c r e a s e d s tab i l i t y fo r c o n t i n u o u s m o n i t o r i n g ; a d j u s t a b l e ou tput f o r use w i t h a recorder; and connec t ions fo r d i g i t a l r e a d o u t or pr in tout

SPECTROPHOTOMETER, Coleman Model 101-0 0 2 , UV range 220 to 37S m > Single beam, diffraction grating type, a.c. line operated, with fixed bandpass of approximately 10 ιημ. With deu­terium lamp and power supply housed separately. Usable in ultraviolet range down to 220 ιημ. Dimensions: 16 inches long X 11 inches deep X 63̂ 2 inches high. Simplicity of operation makes this instrument suitable for routine general analysis and for educational use. Wide Range Phototube. Single tube, with detectors of antimony-cesium and silver-cesium, covers range 220 to 900 ταμ. Energy Recording. Terminal jack is provided with output adjustable 0 to 200 mv for use with a recorder. Linear Wavelength Control. Drum scale 200 to 970 ταμ in 1.8 mm spaced divisions corresponding to 5 ταμ. Meter Scale. Mirrored 5H-in ch scale, graduated 0 to 110% transmittance and —0.04 to 2.0 absorbance.

Performance Specifications Bandpass. Approximately 10 ταμ throughout range. Photometric Accuracy. Transmittance ±0 .5%; absorb­ance ±0.006 at 0.4. Photometric Reproducibility. Transmittance 0.2%. Wavelength Accuracy. Better than +2.5 ιημ throughout range. Slits. Fixed; entrance 0.3 mm wide; exit 1.2 mm wide. Stray Light. Less than 0.5% Τ at 340 ταμ. Celi Path. Light path 5, 10 or 20 mm; 4~place Holder.

Def ailed bulletins

9095-F10. UV Spectrophotometer, Thomas modified Coleman 101-002, range 220 to 375 ιημ, as described. Complete with deuterium lamp and power supply, 4-place cell holder, set of 2 fused silica cells with eovers, etc. For 115 volts, 60 eye. a.c 1,475.00 NOTE—Model 101 is also available with tungsten lamp and power supply for use in the range 340 to 900 mn. Information on request.

^ ί

DIGITAL CONVERTER, Thomas. Prints absorb­ance, transmittance or concentration 4-digiO readings on tape wi th 4-digit sample identifica­tion numbers in adjacent column. Operates from output of various Thomas Readouts.

im&M#d Ύ

sent upon request.

ARTHUR H. THOMAS COMPANY Scientific Apparatus and Reagents

V I N E S T R E E T AT 3 R D · P . O . B O X 7 7 9 « P H I U A O E L P H I A 5 , P A . , U . S . A .