terayon bw3500 cmts (5161) - ca...

27
Terayon BW3500 CMTS Management Module Guide Document 5161

Upload: phamminh

Post on 27-Sep-2018

226 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: Terayon BW3500 CMTS (5161) - CA Technologiesehealth-spectrum.ca.com/support/secure/products/Spectrum_Doc/spec... · Terayon BW3500 CMTS Management Module Guide Page 4 Document 5161

Terayon BW3500 CMTSManagement Module Guide

Document 5161

Page 2: Terayon BW3500 CMTS (5161) - CA Technologiesehealth-spectrum.ca.com/support/secure/products/Spectrum_Doc/spec... · Terayon BW3500 CMTS Management Module Guide Page 4 Document 5161

Terayon BW3500 CMTSManagement Module Guide

Page 2

Document 5161

NoticeCopyright Notice Copyright © 2004 - present by Aprisma Management Technologies, Inc. All rights reserved worldwide. Use, duplication, or disclosure by the United States government is subject to the restrictions set forth in DFARS 252.227-7013(c)(1)(ii) and FAR 52.227-19.

Liability Disclaimer Aprisma Management Technologies, Inc. (“Aprisma”) reserves the right to make changes in specifications and other information contained in this document without prior notice. In all cases, the reader should contact Aprisma to inquire if any changes have been made.

The hardware, firmware, or software described in this manual is subject to change without notice.

IN NO EVENT SHALL APRISMA, ITS EMPLOYEES, OFFICERS, DIRECTORS, AGENTS, OR AFFILIATES BE LIABLE FOR ANY INCIDENTAL, INDIRECT, SPECIAL, OR CONSEQUENTIAL DAMAGES WHATSOEVER (INCLUDING BUT NOT LIMITED TO LOST PROFITS) ARISING OUT OF OR RELATED TO THIS MANUAL OR THE INFORMATION CONTAINED IN IT, EVEN IF APRISMA HAS BEEN ADVISED OF, HAS KNOWN, OR SHOULD HAVE KNOWN, THE POSSIBILITY OF SUCH DAMAGES.

Trademark, Service Mark, and Logo Information SPECTRUM, IMT, and the SPECTRUM IMT/VNM logo are registered trademarks of Aprisma Management Technologies, Inc., or its affiliates. APRISMA, APRISMA MANAGEMENT TECHNOLOGIES, the APRISMA MANAGEMENT TECHNOLOGIES logo, MANAGE WHAT MATTERS, DCM, VNM, SpectroGRAPH, SpectroSERVER, Inductive Modeling Technology, Device Communications Manager, SPECTRUM Security Manager, and Virtual Network Machine are unregistered trademarks of Aprisma Management Technologies, Inc., or its affiliates. For a complete list of Aprisma trademarks, service marks, and trade names, go to:

http://www.aprisma.com/support/secure/manuals/trademark-list.htm

All referenced trademarks, service marks, and trade names identified in this document, whether registered or unregistered, are the intellectual property of their respective owners. No rights are granted by Aprisma Management Technologies, Inc., to use such marks, whether by implication, estoppel, or otherwise. If you have comments or concerns about trademark or copyright references, please send an e-mail to [email protected]; we will do our best to help.

Restricted Rights Notice (Applicable to licenses to the United States government only.)This software and/or user documentation is/are provided with RESTRICTED AND LIMITED RIGHTS. Use, duplication, or disclosure by the government is subject to restrictions as set forth in FAR 52.227-14 (June 1987) Alternate III(g)(3) (June 1987), FAR 52.227-19 (June 1987), or DFARS 52.227-7013(c)(1)(ii) (June 1988), and/or in similar or successor clauses in the FAR or DFARS, or in the DOD or NASA FAR Supplement, as applicable. Contractor/manufacturer is Aprisma Management Technologies, Inc. In the event the government seeks to obtain the software pursuant to standard commercial practice, this software agreement, instead of the noted regulatory clauses, shall control the terms of the government's license.

Virus Disclaimer Aprisma makes no representations or warranties to the effect that the licensed software is virus-free. Aprisma has tested its software with current virus-checking technologies. However, because no antivirus system is 100-percent effective, we strongly recommend that you write protect the licensed software and verify (with an antivirus system with which you have confidence) that the licensed software, prior to installation, is virus-free.

Contact Information Aprisma Management Technologies, Inc., 273 Corporate Drive, Portsmouth, NH 03801 USA

Phone: 603.334.2100U.S. toll-free: 877.468.1448Web site: http://www.aprisma.com

Page 3: Terayon BW3500 CMTS (5161) - CA Technologiesehealth-spectrum.ca.com/support/secure/products/Spectrum_Doc/spec... · Terayon BW3500 CMTS Management Module Guide Page 4 Document 5161

Terayon BW3500 CMTSManagement Module Guide

Page 3

Document 5161

Contents

Notice ........................................................................................... 2

Preface ......................................................................................... 4

Intended Audience ..................................................................... 4

Text Conventions ....................................................................... 4

Document Feedback ................................................................... 5

Online Documents ...................................................................... 5

Required Reading ....................................................................... 5

Overview ...................................................................................... 7

Device Support .......................................................................... 7

Device MIB Support ................................................................... 8

Traps, Events, and Alarms ............................................................ 9

Standard Trap Support ............................................................... 9

Device Specific Trap Support ......................................................10

Application Support .................................................................... 23

RFC and IEEE Standard Applications ............................................23

Device Views .............................................................................. 24

Cable Status ............................................................................24

Signal Quality ......................................................................24

Entity Tables ............................................................................25

Physical Logical Tables ..........................................................25

Index .......................................................................................... 26

Page 4: Terayon BW3500 CMTS (5161) - CA Technologiesehealth-spectrum.ca.com/support/secure/products/Spectrum_Doc/spec... · Terayon BW3500 CMTS Management Module Guide Page 4 Document 5161

Terayon BW3500 CMTSManagement Module Guide

Page 4

Document 5161

Preface

Welcome to the user guide for SPECTRUM’s Terayon BW3500 CMTS (SM-TRN1001) management module.

Please take a moment to read through this short preface, which explains how the information in this guide is organized and presented and lets you know how to access information about other SPECTRUM products.

In this section:

Intended Audience [page 4]

Text Conventions [page 4]

Document Feedback [page 5]

Online Documents [page 5]

Required Reading [page 5]

Intended Audience

This guide is intended for users of SPECTRUM’s Terayon BW3500 CMTS (SM-TRN1001) management module.

For general information about device management using SPECTRUM and explanations of SPECTRUM functionality and navigation techniques, refer to the topics listed under Required Reading [page 5].

Text Conventions

The following text conventions are used in this document:

Element Convention Used Example

User-supplied parameter names

Courier and Italic in angle brackets <>.

The user needs to type the password in place of <password>.

On-screen text Courier The following line displays:

path=”/audit”

Page 5: Terayon BW3500 CMTS (5161) - CA Technologiesehealth-spectrum.ca.com/support/secure/products/Spectrum_Doc/spec... · Terayon BW3500 CMTS Management Module Guide Page 4 Document 5161

Terayon BW3500 CMTSManagement Module Guide

Page 5

Document 5161

Document Feedback

Please send feedback regarding SPECTRUM documents to the following e-mail address:

[email protected]

Thank you for helping us improve our documentation.

Online Documents

SPECTRUM documents are available online at:

http://www.aprisma.com/support/secure/manuals

Check this site for the latest updates and additions.

Required Reading

To use this documentation effectively, you must be familiar with the information covered by the SPECTRUM documents listed below.

• Getting Started with SPECTRUM for Operators (1763)

• Getting Started with SPECTRUM for Administrators (0985)

• How to Manage Your Network with SPECTRUM (1909)

• SPECTRUM Views (2517)

• SPECTRUM Menus (2519)

User-typed text Courier Type the following path name: C:\ABC\lib\db

Cross-references Underlined and hypertext-blue

See Document Feedback [page 5].

References to SPECTRUM documents (title and number)

Italic SPECTRUM Installation Guide (0675)

Functionality enabled by SPECTRUM Alarm Notification Manager (SANM)

SANM in brackets []. [SANM] AGE_FIELD_ID

Element Convention Used Example

Page 6: Terayon BW3500 CMTS (5161) - CA Technologiesehealth-spectrum.ca.com/support/secure/products/Spectrum_Doc/spec... · Terayon BW3500 CMTS Management Module Guide Page 4 Document 5161

Terayon BW3500 CMTSManagement Module Guide

Page 6

Document 5161

• SPECTRUM Icons (2518)

• Application View and MIBs (2560)

• SPECTRUM Software Release Notice

Page 7: Terayon BW3500 CMTS (5161) - CA Technologiesehealth-spectrum.ca.com/support/secure/products/Spectrum_Doc/spec... · Terayon BW3500 CMTS Management Module Guide Page 4 Document 5161

Terayon BW3500 CMTSManagement Module Guide

Page 7

Document 5161

Overview

This section introduces the SPECTRUM documentation for the Terayon BW3500 CMTS management module.

In this section:

Device Support [page 7]

Device MIB Support [page 8]

Device Support

SPECTRUM management module SM-TRN1001 provides modeling for the following Terayon BW3500 CMTS devices (Table 1). Figure 1 shows the Device Icon in the Topology view.

Table 1: Supported Devices, Firmware, and Model Type

Figure 1: Device Icon

The BW 3500 Intelligent Access Cable Modem Termination System (CMTS) can enable up to 30 Mbps per upstream channel and 50% higher spectral efficiency to existing cable infrastructures. It provides carrier-class redundancy with no single point of failure across the entire system and is deployable in any DOCSIS mode (DOCSIS 1.0, 1.1 or 2.0). The most critical protocols, such as OSPF v2, RIP v1/v2, and MPLS are supported and enable the BW 3500 to seamlessly fit within the infrastructure. The BW 3500 also offers comprehensive security features to prevent Denial of Service attacks and other suspicious activity.

Device Firmware Revision Model Type

BW3500 4.0.1.0.15 BlueWave

Page 8: Terayon BW3500 CMTS (5161) - CA Technologiesehealth-spectrum.ca.com/support/secure/products/Spectrum_Doc/spec... · Terayon BW3500 CMTS Management Module Guide Page 4 Document 5161

Terayon BW3500 CMTSManagement Module Guide

Page 8

Document 5161

Device MIB Support

SPECTRUM supports a number of device-specific MIBs for the Terayon BW3500 CMTS (SM-TRN1001) management module. These MIBs are shown in Table 2.

Table 2: Device-Specific MIBs

Device-Specific MIBs

Terayon Proprietary

BLUEWAVE-ARP.mib

BLUEWAVE-BANDWIDTH.mib

BLUEWAVE-BPI-MULTICAST.mib

BLUEWAVE-CMTS.mib

BLUEWAVE-ENTITY-PRIVATE.mib

BLUEWAVE-EVENT-LOG-MANAGEMENT.mib

BLUEWAVE-FLOW-MANAGER.mib

BLUEWAVE-FWDR-SUBMGM.mib

BLUEWAVE-HWMGR.mib

BLUEWAVE-INTERFACE.mib

BLUEWAVE-IP-CONFIG.mib

BLUEWAVE-LAG.mib

BLUEWAVE-LC-CONFIG.mib

BLUEWAVE-LC-PARAMS.mib

BLUEWAVE-MCST.mib

BLUEWAVE-MPLS.mib

BLUEWAVE-PACKET-CABLE.mib

BLUEWAVE-RCS.mib

BLUEWAVE-SYSTEM-CONFIG.mib

BLUEWAVE-SYSTEM.mib

BLUEWAVE-TRAPS.mib

BLUEWAVE-VRF-ROUTE.mib

Page 9: Terayon BW3500 CMTS (5161) - CA Technologiesehealth-spectrum.ca.com/support/secure/products/Spectrum_Doc/spec... · Terayon BW3500 CMTS Management Module Guide Page 4 Document 5161

Document 5161Terayon BW3500 CMTSManagement Module Guide

Page 9

Traps, Events, and Alarms

This section describes the traps supported by the Terayon BW3500 CMTS (SM-TRN1001) management module.

In This Section

Standard Trap Support [page 9]

Device Specific Trap Support [page 10]

Standard Trap Support

Table 3 shows the standard traps that are supported.

Table 3: Standard Traps

Trap Name / OID Varbinds Rule / Varbind(s)

Varbind Value

Event Generated

Alarm Generated / Severity

Varbind Disciminators

linkDown 1.3.6.1.6.3.1.1.5.3

standard N/A N/A 0x220001 0x220001 ifIndex

linkUp 1.3.6.1.6.3.1.1.5.4

standard N/A N/A 0x220002 0x220002 ifIndex

coldStart 1.3.6.1.6.3.1.1.5.1

standard N/A N/A 0x10306 N/A N/A

authenticationFailure 1.3.6.1.6.3.1.1.5.5

standard N/A N/A 0x0001030a 0x0001030a N/A

Page 10: Terayon BW3500 CMTS (5161) - CA Technologiesehealth-spectrum.ca.com/support/secure/products/Spectrum_Doc/spec... · Terayon BW3500 CMTS Management Module Guide Page 4 Document 5161

Document 5161Terayon BW3500 CMTSManagement Module Guide

Page 10

Device Specific Trap Support

Table 4 shows the device specific traps that are supported.

Table 4: Device Specific Trap Support

newRoot 1.3.6.1.2.1.17.6.1

standard N/A N/A NA NA N/A

Trap Name / OID Varbinds Rule / Varbind(s)

Varbind Value

Event Generated

Alarm Generated / Severity

Varbind Disciminators

bwFanFailure 1.3.6.1.4.1.1456.3.1.1.100.0.1

docsDevEvLevel 1.3.6.1.2.1.69.1.5.8.1.5 docsDevEvId 1.3.6.1.2.1.69.1.5.8.1.6 docsDevEvText 1.3.6.1.2.1.69.1.5.8.1.7

Initial N/A 0x033b0100 N/A N/A

Condition Rule 2242904322 Unit Failed

0x033b0200 0x033b0200 docsDevEvText

2242904327 Unit Removed

0x033b0201 0x033b0201 docsDevEvText

bwPowerFailure 1.3.6.1.4.1.1456.3.1.1.100.0.2

docsDevEvLevel 1.3.6.1.2.1.69.1.5.8.1.5 docsDevEvId 1.3.6.1.2.1.69.1.5.8.1.6 docsDevEvText 1.3.6.1.2.1.69.1.5.8.1.8

N/A N/A 0x033b0101 0x033b0101 docsDevEvText

Trap Name / OID Varbinds Rule / Varbind(s)

Varbind Value

Event Generated

Alarm Generated / Severity

Varbind Disciminators

Page 11: Terayon BW3500 CMTS (5161) - CA Technologiesehealth-spectrum.ca.com/support/secure/products/Spectrum_Doc/spec... · Terayon BW3500 CMTS Management Module Guide Page 4 Document 5161

Document 5161Terayon BW3500 CMTSManagement Module Guide

Page 11

bwExpCardFailure 1.3.6.1.4.1.1456.3.1.1.100.0.3

docsDevEvLevel 1.3.6.1.2.1.69.1.5.8.1.5 docsDevEvId 1.3.6.1.2.1.69.1.5.8.1.6 docsDevEvText 1.3.6.1.2.1.69.1.5.8.1.9

N/A N/A 0x033b0102 0x033b0102 N/A

bwSccFailure 1.3.6.1.4.1.1456.3.1.1.100.0.4

docsDevEvLevel 1.3.6.1.2.1.69.1.5.8.1.5 docsDevEvId 1.3.6.1.2.1.69.1.5.8.1.6 docsDevEvText 1.3.6.1.2.1.69.1.5.8.1.10

N/A N/A 0x033b0103 0x033b0103 N/A

bwSccHighTemp 1.3.6.1.4.1.1456.3.1.1.100.0.5

docsDevEvLevel 1.3.6.1.2.1.69.1.5.8.1.5 docsDevEvId 1.3.6.1.2.1.69.1.5.8.1.6 docsDevEvText 1.3.6.1.2.1.69.1.5.8.1.11

N/A N/A 0x033b0104 0x033b0104 N/A

bwLcFailure 1.3.6.1.4.1.1456.3.1.1.100.0.6

docsDevEvLevel 1.3.6.1.2.1.69.1.5.8.1.5 docsDevEvId 1.3.6.1.2.1.69.1.5.8.1.6 docsDevEvText 1.3.6.1.2.1.69.1.5.8.1.12

Initial N/A 0x033b0105 N/A N/A

Condition Rule 2242904328 Unknown fatal event

0x033b0206 0x033b0206 docsDevEvText

Trap Name / OID Varbinds Rule / Varbind(s)

Varbind Value

Event Generated

Alarm Generated / Severity

Varbind Disciminators

Page 12: Terayon BW3500 CMTS (5161) - CA Technologiesehealth-spectrum.ca.com/support/secure/products/Spectrum_Doc/spec... · Terayon BW3500 CMTS Management Module Guide Page 4 Document 5161

Document 5161Terayon BW3500 CMTSManagement Module Guide

Page 12

2242904329 Heartbeat with SCC <scc-id> failed

0x033b0207 0x033b0207 docsDevEvText

2242904576 LCP out of buffers

0x033b0208 0x033b0208 docsDevEvText

2242904577 UPP out of buffers

0x033b0209 0x033b0209 docsDevEvText

2242904578 Up converter failed

0x033b020a 0x033b020a docsDevEvText

2242904579 DMAC failed

0x033b020b 0x033b020b docsDevEvText

2242904580 UMAC failed

0x033b020c 0x033b020c docsDevEvText

2242904581 Temperature exceeds threshold

0x033b020d 0x033b020d docsDevEvText

2242904582 Voltage exceeds threshold

0x033b020e 0x033b020e docsDevEvText

Trap Name / OID Varbinds Rule / Varbind(s)

Varbind Value

Event Generated

Alarm Generated / Severity

Varbind Disciminators

Page 13: Terayon BW3500 CMTS (5161) - CA Technologiesehealth-spectrum.ca.com/support/secure/products/Spectrum_Doc/spec... · Terayon BW3500 CMTS Management Module Guide Page 4 Document 5161

Document 5161Terayon BW3500 CMTSManagement Module Guide

Page 13

2242904583LCP out of FCC buffer descriptors

0x033b020f 0x033b020f docsDevEvText

2242904584UPP out of FCC buffer descriptors

0x033b0210 0x033b0210 docsDevEvText

2242904585UPP out of IDMA buffers

0x033b0211 0x033b0211 docsDevEvText

2242904586LCP stack overflow

0x033b0212 0x033b0212 docsDevEvText

2242904587UPP stack overflow

0x033b0213 0x033b0213 docsDevEvText

2242904588High LCP CPU usage

0x033b0214 0x033b0214 docsDevEvText

2242904589High UPP CPU usage

0x033b0215 0x033b0215 docsDevEvText

2242904590LCP task suspended

0x033b0216 0x033b0216 docsDevEvText

Trap Name / OID Varbinds Rule / Varbind(s)

Varbind Value

Event Generated

Alarm Generated / Severity

Varbind Disciminators

Page 14: Terayon BW3500 CMTS (5161) - CA Technologiesehealth-spectrum.ca.com/support/secure/products/Spectrum_Doc/spec... · Terayon BW3500 CMTS Management Module Guide Page 4 Document 5161

Document 5161Terayon BW3500 CMTSManagement Module Guide

Page 14

2242904591UPP task suspended

0x033b0217 0x033b0217 docsDevEvText

2242904592LCP task deleted

0x033b0218 0x033b0218 docsDevEvText

2242904593UPP task deleted

0x033b0219 0x033b0219 docsDevEvText

2242904594LCP FCC failed

0x033b021a 0x033b021a docsDevEvText

2242904595UPP FCC failed

0x033b021b 0x033b021b docsDevEvText

2242904596UPP serial communication controller port failed

0x033b021c 0x033b021c docsDevEvText

2242904597LCP failed

0x033b021d 0x033b021d docsDevEvText

2242904598UPP failed

0x033b021e 0x033b021e docsDevEvText

2242904599Initialization failure

0x033b021f 0x033b021f docsDevEvText

Trap Name / OID Varbinds Rule / Varbind(s)

Varbind Value

Event Generated

Alarm Generated / Severity

Varbind Disciminators

Page 15: Terayon BW3500 CMTS (5161) - CA Technologiesehealth-spectrum.ca.com/support/secure/products/Spectrum_Doc/spec... · Terayon BW3500 CMTS Management Module Guide Page 4 Document 5161

Document 5161Terayon BW3500 CMTSManagement Module Guide

Page 15

2242904600Communication with SCC failed

0x033b0220 0x033b0220 docsDevEvText

2242904601Upstream path failed

0x033b0221 0x033b0221 docsDevEvText

2242904602DMAC configuration failed

0x033b0222 0x033b0222 docsDevEvText

2242904603Timer failed

0x033b0223 0x033b0223 docsDevEvText

2242904604Failed to get interface mapping

0x033b0224 0x033b0224 docsDevEvText

2242904605Failed to get configuration

0x033b0225 0x033b0225 docsDevEvText

2242904606UPP Watchdog Timer expired

0x033b0226 0x033b0226 docsDevEvText

Trap Name / OID Varbinds Rule / Varbind(s)

Varbind Value

Event Generated

Alarm Generated / Severity

Varbind Disciminators

Page 16: Terayon BW3500 CMTS (5161) - CA Technologiesehealth-spectrum.ca.com/support/secure/products/Spectrum_Doc/spec... · Terayon BW3500 CMTS Management Module Guide Page 4 Document 5161

Document 5161Terayon BW3500 CMTSManagement Module Guide

Page 16

2242904607LCP Watchdog Timer expired

0x033b0227 0x033b0227 docsDevEvText

2242904608UPP Checkstop reset

0x033b0228 0x033b0228 docsDevEvText

2242904609LCP Checkstop reset

0x033b0229 0x033b0229 docsDevEvText

2242904610UPP out of IDMA buffer descriptors

0x033b022a 0x033b022a docsDevEvText

2242904611UPP MAP processing failed

0x033b022b 0x033b022b docsDevEvText

2242904612Mailbox operation failed

0x033b022c 0x033b022c docsDevEvText

2242904613NVRAM battery failed

0x033b022d 0x033b022d docsDevEvText

Trap Name / OID Varbinds Rule / Varbind(s)

Varbind Value

Event Generated

Alarm Generated / Severity

Varbind Disciminators

Page 17: Terayon BW3500 CMTS (5161) - CA Technologiesehealth-spectrum.ca.com/support/secure/products/Spectrum_Doc/spec... · Terayon BW3500 CMTS Management Module Guide Page 4 Document 5161

Document 5161Terayon BW3500 CMTSManagement Module Guide

Page 17

2242904614LCP MAP Generation failed

0x033b022e 0x033b022e docsDevEvText

bwSccRedundancyFailure 1.3.6.1.4.1.1456.3.1.1.100.0.7

docsDevEvLevel 1.3.6.1.2.1.69.1.5.8.1.5 docsDevEvId 1.3.6.1.2.1.69.1.5.8.1.6 docsDevEvText 1.3.6.1.2.1.69.1.5.8.1.13

Initial N/A 0x033b0106 N/A N/A

Condition Rule 2242904450 Redundancy sync failed

0x033b0202 0x033b0202 docsDevEvText

2242904453 Redundancy protection stopped

0x033b0203 0x033b0203 docsDevEvText

bwLcRedundancyFailure 1.3.6.1.4.1.1456.3.1.1.100.0.8

docsDevEvLevel 1.3.6.1.2.1.69.1.5.8.1.5 docsDevEvId 1.3.6.1.2.1.69.1.5.8.1.6 docsDevEvText 1.3.6.1.2.1.69.1.5.8.1.14

Initial N/A 0x033b0107 N/A N/A

Condition Rule 2242905089 LC <lc-id> synchronization with LC <lc-id> failed.

0x033b0204 0x033b0204 docsDevEvText

Trap Name / OID Varbinds Rule / Varbind(s)

Varbind Value

Event Generated

Alarm Generated / Severity

Varbind Disciminators

Page 18: Terayon BW3500 CMTS (5161) - CA Technologiesehealth-spectrum.ca.com/support/secure/products/Spectrum_Doc/spec... · Terayon BW3500 CMTS Management Module Guide Page 4 Document 5161

Document 5161Terayon BW3500 CMTSManagement Module Guide

Page 18

2242905094 Redundancy group protection stopped.

0x033b0205 0x033b0205 docsDevEvText

docsDevCmtsInitRegReqFailTrap 1.3.6.1.2.1.69.2.1.3.0.1

docsDevEvLevel,docsDevEvId,docsDevEvText,docsIfCmtsCmStatusDocsisMode,docsIfCmtsCmStatusMacAddress,docsIfDocsisCapability,ifPhysAddress

Initial Trap N/A 0x36c0000 N/A N/A

docsDevCmtsInitRegRspFailTrap 1.3.6.1.2.1.69.2.1.3.0.2

docsDevEvLevel,docsDevEvId,docsDevEvText,docsIfCmtsCmStatusDocsisMode,docsIfCmtsCmStatusMacAddress,docsIfDocsisCapability,ifPhysAddress

Initial Trap N/A 0x36c0001 N/A N/A

Trap Name / OID Varbinds Rule / Varbind(s)

Varbind Value

Event Generated

Alarm Generated / Severity

Varbind Disciminators

Page 19: Terayon BW3500 CMTS (5161) - CA Technologiesehealth-spectrum.ca.com/support/secure/products/Spectrum_Doc/spec... · Terayon BW3500 CMTS Management Module Guide Page 4 Document 5161

Document 5161Terayon BW3500 CMTSManagement Module Guide

Page 19

docsDevCmtsInitRegAckFailTrap 1.3.6.1.2.1.69.2.1.3.0.3

docsDevEvLevel,docsDevEvId,docsDevEvText,docsIfCmtsCmStatusDocsisMode,docsIfCmtsCmStatusMacAddress,docsIfDocsisCapability,ifPhysAddress

Initial Trap N/A 0x36c0002 N/A N/A

docsDevCmtsDynServReqFailTrap 1.3.6.1.2.1.69.2.1.3.0.4

docsDevEvLevel,docsDevEvId,docsDevEvText,docsIfCmtsCmStatusDocsisMode,docsIfCmtsCmStatusMacAddress,docsIfDocsisCapability,ifPhysAddress

Initial Trap N/A 0x36c0003 N/A N/A

docsDevCmtsDynServRspFailTrap 1.3.6.1.2.1.69.2.1.3.0.5

docsDevEvLevel,docsDevEvId,docsDevEvText,docsIfCmtsCmStatusDocsisMode,docsIfCmtsCmStatusMacAddress,docsIfDocsisCapability,ifPhysAddress

Initial Trap N/A 0x36c0004 N/A N/A

Trap Name / OID Varbinds Rule / Varbind(s)

Varbind Value

Event Generated

Alarm Generated / Severity

Varbind Disciminators

Page 20: Terayon BW3500 CMTS (5161) - CA Technologiesehealth-spectrum.ca.com/support/secure/products/Spectrum_Doc/spec... · Terayon BW3500 CMTS Management Module Guide Page 4 Document 5161

Document 5161Terayon BW3500 CMTSManagement Module Guide

Page 20

docsDevCmtsDynServAckFailTrap 1.3.6.1.2.1.69.2.1.3.0.6

docsDevEvLevel,docsDevEvId,docsDevEvText,docsIfCmtsCmStatusDocsisMode,docsIfCmtsCmStatusMacAddress,docsIfDocsisCapability,ifPhysAddress

Initial Trap N/A 0x36c0005 N/A N/A

docsDevCmtsBpiInitTrap 1.3.6.1.2.1.69.2.1.3.0.7

docsDevEvLevel,docsDevEvId,docsDevEvText,docsIfCmtsCmStatusDocsisMode,docsIfCmtsCmStatusMacAddress,docsIfDocsisCapability,ifPhysAddress

Initial Trap N/A 0x36c0006 N/A N/A

docsDevCmtsBPKMTrap 1.3.6.1.2.1.69.2.1.3.0.8

docsDevEvLevel,docsDevEvId,docsDevEvText,docsIfCmtsCmStatusDocsisMode,docsIfCmtsCmStatusMacAddress,docsIfDocsisCapability,ifPhysAddress

Initial Trap N/A 0x36c0007 N/A N/A

Trap Name / OID Varbinds Rule / Varbind(s)

Varbind Value

Event Generated

Alarm Generated / Severity

Varbind Disciminators

Page 21: Terayon BW3500 CMTS (5161) - CA Technologiesehealth-spectrum.ca.com/support/secure/products/Spectrum_Doc/spec... · Terayon BW3500 CMTS Management Module Guide Page 4 Document 5161

Document 5161Terayon BW3500 CMTSManagement Module Guide

Page 21

docsDevCmtsDynamicSATrap 1.3.6.1.2.1.69.2.1.3.0.9

docsDevEvLevel,docsDevEvId,docsDevEvText,docsIfCmtsCmStatusDocsisMode,docsIfCmtsCmStatusMacAddress,docsIfDocsisCapability,ifPhysAddress

Initial Trap N/A 0x36c0008 N/A N/A

docsDevCmtsDCCReqFailTrap 1.3.6.1.2.1.69.2.1.3.0.10

docsDevEvLevel,docsDevEvId,docsDevEvText,docsIfCmtsCmStatusDocsisMode,docsIfCmtsCmStatusMacAddress,docsIfDocsisCapability,ifPhysAddress

Initial Trap N/A 0x36c0009 N/A N/A

docsDevCmtsDCCRspFailTrap 1.3.6.1.2.1.69.2.1.3.0.11

docsDevEvLevel,docsDevEvId,docsDevEvText,docsIfCmtsCmStatusDocsisMode,docsIfCmtsCmStatusMacAddress,docsIfDocsisCapability,ifPhysAddress

Initial Trap N/A 0x36c000a N/A N/A

Trap Name / OID Varbinds Rule / Varbind(s)

Varbind Value

Event Generated

Alarm Generated / Severity

Varbind Disciminators

Page 22: Terayon BW3500 CMTS (5161) - CA Technologiesehealth-spectrum.ca.com/support/secure/products/Spectrum_Doc/spec... · Terayon BW3500 CMTS Management Module Guide Page 4 Document 5161

Document 5161Terayon BW3500 CMTSManagement Module Guide

Page 22

docsDevCmtsDCCAckFailTrap 1.3.6.1.2.1.69.2.1.3.0.12

docsDevEvLevel,docsDevEvId,docsDevEvText,docsIfCmtsCmStatusDocsisMode,docsIfCmtsCmStatusMacAddress,docsIfDocsisCapability,ifPhysAddress

Initial Trap N/A 0x36c000b N/A N/A

Trap Name / OID Varbinds Rule / Varbind(s)

Varbind Value

Event Generated

Alarm Generated / Severity

Varbind Disciminators

Page 23: Terayon BW3500 CMTS (5161) - CA Technologiesehealth-spectrum.ca.com/support/secure/products/Spectrum_Doc/spec... · Terayon BW3500 CMTS Management Module Guide Page 4 Document 5161

Terayon BW3500 CMTSManagement Module Guide

Page 23

Document 5161

Application Support

This section describes the applications supported by the Terayon BW3500 CMTS (SM-TRN1001) management module.

In This Section

RFC and IEEE Standard Applications [page 23]

RFC and IEEE Standard Applications

The Terayon BW3500 CMTS management module supports various RFC and IEEE standard applications. The applications are created and associated with the device model based on the specific device’s capabilities. The following guides contain complete documentation for each of the standard applications supported by SPECTRUM:

• Bridging Applications (2562)

• MIB II Applications (2561)

• Routing Applications (3080)

• Technology Applications (5065)

• Transmission Applications (5064)

Page 24: Terayon BW3500 CMTS (5161) - CA Technologiesehealth-spectrum.ca.com/support/secure/products/Spectrum_Doc/spec... · Terayon BW3500 CMTS Management Module Guide Page 4 Document 5161

Terayon BW3500 CMTSManagement Module Guide

Page 24

Document 5161

Device Views

This section describes device-specific views for the Terayon BW3500 CMTS that are accessible from the Icon Subviews menu of the Device icon.

In This Section

Cable Status [page 24]

Entity Tables [page 25]

Cable Status

Note: From the Icon Subviews menu for the device icon, select Cable Status.

This menu selection allows you to access the Signal Quality sub-menu.

Signal Quality

Note: From the Icon Subviews menu for the device icon, select Cable Status > Signal Quality.

The Signal Quality table provides information on objects from the docsIfSignalQualityTable in the RFC2670 MIB.

Page 25: Terayon BW3500 CMTS (5161) - CA Technologiesehealth-spectrum.ca.com/support/secure/products/Spectrum_Doc/spec... · Terayon BW3500 CMTS Management Module Guide Page 4 Document 5161

Terayon BW3500 CMTSManagement Module Guide

Page 25

Document 5161

Entity Tables

Note: From the Icon Subviews menu for the device icon, select Entity Tables.

This menu selection allows you to access the Physical/Logical Tables sub-menu.

Physical Logical Tables

Note: From the Icon Subviews menu for the device icon, select Entity Tables > Physical/Logical Tables.

The Entity tables provide information on objects from the entPhysical and entLogical tables in the RFC2737 MIB.

Page 26: Terayon BW3500 CMTS (5161) - CA Technologiesehealth-spectrum.ca.com/support/secure/products/Spectrum_Doc/spec... · Terayon BW3500 CMTS Management Module Guide Page 4 Document 5161

Terayon BW3500 CMTSManagement Module Guide

Page 26

Document 5161

Index

CCable Status [24]

Ddevice-specific MIBs [8]docsIfSignalQualityTable [24]

EEntity Tables [25]entLogical table [25]entPhysical table [25]

FFirmware [7]

MMIB Support [8]Model Type [7]

PPhysical/Logical Tables [25]

RRFC2670 MIB [24]RFC2737 MIB [25]

SSignal Quality [24]standard traps [9]Supported Devices [7]

Page 27: Terayon BW3500 CMTS (5161) - CA Technologiesehealth-spectrum.ca.com/support/secure/products/Spectrum_Doc/spec... · Terayon BW3500 CMTS Management Module Guide Page 4 Document 5161

Terayon BW3500 CMTSManagement Module Guide

Page 27

Document 5161

TTrap Support [9]