wenglor lasik sensor
TRANSCRIPT
-
Error Output
Analog Output
RS-232 Interface
Par
t Num
ber
Accessories
03 = Error Indicator07 = Selector Switch12 = Analog Output Indicator24 = Plus Button25 = Minus Button63 = Analog Output Current Indicator
Mounting Bracket WP
Serial Interface Adapter S232W2
P 7
07
25
24
63 12 03
Ctrl.Panel
00.0
5.0
10
a U
/V
c
Connection Diagram No.
Control Panel No.
Suitable Plug No.
Optical Data
Working Range 40...160 mm
Measuring Range 120 mm
Resolution < 20 m
Resolution (Speed-Mode) < 30 m
Linearity 0.1 %
Linearity (Speed-Mode) 0.2 %
Light Source Laser (red)
Wave Length 660 nm
Service Life (T = +25C) 100000 h
Laser Protection Class (EN 60825-1) 2
max. Ambient Light 10000 Lux
Electrical Data
18...30 V DCSupply Voltage
< 80 mACurrent Consumption (Ub = 24V)
750 HzCut-Off Frequency
300 HzCut-Off Frequency (Resolution-Mode)
< 660 sResponse Time
< 1660 sResponse Time (Resolution Mode)
< 10 m/CTemperature Drift
-25...50 CTemperature Range
0...10 VAnalog Output
< 1 mACurrent Load Voltage Output
4...20 mAAnalog Output
< 500 OhmCurrent Output Load Resistance
RS-232Interface
38400 BdBaud Rate
Mechanical Data
Teach-InAdjustment
PlasticHousing
IP 67Protection Mode
M 12x1Connection
50 VProtective Insulation, Rated Voltage
PlugVersion
Reflex Sensors
for Measuring Tasks
Transmitter Diode1 =
Receiver Diode2 =
High resolution 20m (Resolution-Mode)
Linearity 0,1% (Resolution-Mode)
Response Time