arthur h. thomas company

1
Thomas... COMBINATION pH ELECTRODES For samples from 0.2 ml to a tankful Rugged tips FAST... FAST... FAST with PRECISION COMBINATION ELECTRODES,Thomas.Con- sisting of a glass electrode and a silver-silver chloride reference electrode sealed into a single body. Bulb wall thickness and strength provide a sturdier electrode than heretofore available. The single J4-inch stem can be used with samples of small volume as well as with larger quantities, and is more convenient for transfer by hand from sample to sample than bringing the sample to electrodes in a fixed position. The glass electrode inner element is shielded from electrostatic effects and stray electrical fields by the KC1 solution of the reference electrode. Port is provided for KC1 refill. Liquid junction is made by a sintered oxide plug sealed into the side of the lower stem 5^-inch above tip. The stable, fast response of this low resistance glass electrode and the short fixed distance between it and the reference electrode junction make the Thomas Combiiiation Electrode particularly valu- able in avoiding «ndpoint overshooting in electro- metric titrations.* The compactness of the design permits use of small vessels and leaves more room for stirrers and buret tips. Electrodes are each 6 inches long. Upper section is J^-inch diameter for use in standard electrode holders. Stem is M-inch diameter over the lower 4-inch length. Can be used with samples as small as 0.2 ml in narrow tubes. Connector plug of the glass electrode fits into the jacks of most existing pH Meters, either directly or through available adapters. 4858-L15. Combination Electrode, Thomas, as above, 6 inches long, range pH 0 to 12, tem- perature range 0 to 75°C, with 30-inch shielded lead 40.00 4858-L60. Ditto, range pH 0 to 14 43.00 *See H. V. Malmstadt and E. H. Piepmeier, Analytical Chemistry, Vol. 37, No. 1 (January, 1965), p. Si Thomas Laboratory Electrodes, see 1968 catalog pages 468-473, 488. Thomas Industrial Electrodes, information upon request. Thomas ARTHUR H. THOMAS COMPANY Scientific Apparatus and Reagents VINE STREET AT 3RD · P.O. BOX 779 · PHILADELPHIA, PA. 19105, U.S.A. Circle No. 144 en Readers' Service Card 114 A . ANALYTICAL CHEMISTRY, VOL. 42, NO. 13, NOVEMBER 1970

Upload: phamhanh

Post on 14-Feb-2017

218 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ARTHUR H. THOMAS COMPANY

Thomas... COMBINATION pH ELECTRODES

For samples from 0.2 ml to a tankful

• Rugged tips

FAST... FAST...

FAST with PRECISION

COMBINATION ELECTRODES,Thomas.Con­sisting of a glass electrode and a silver-silver chloride reference electrode sealed into a single body. Bulb wall thickness and strength provide a sturdier electrode than heretofore available.

The single J4-inch stem can be used with samples of small volume as well as with larger quantities, and is more convenient for transfer by hand from sample to sample than bringing the sample to electrodes in a fixed position.

The glass electrode inner element is shielded from electrostatic effects and stray electrical fields by the KC1 solution of the reference electrode. Port is provided for KC1 refill. Liquid junction is made by a sintered oxide plug sealed into the side of the lower stem 5^-inch above tip.

The stable, fast response of this low resistance glass electrode and the short fixed distance between it and the reference electrode junction make the Thomas Combiiiation Electrode particularly valu­able in avoiding «ndpoint overshooting in electro-metric titrations.* The compactness of the design permits use of small vessels and leaves more room for stirrers and buret tips.

Electrodes are each 6 inches long. Upper section is J^-inch diameter for use in standard electrode holders. Stem is M-inch diameter over the lower 4-inch length. Can be used with samples as small as 0.2 ml in narrow tubes.

Connector plug of the glass electrode fits into the jacks of most existing pH Meters, either directly or through available adapters.

4858-L15. Combinat ion Electrode, Thomas, as above, 6 inches long, range pH 0 to 12, tem­perature range 0 to 75°C, with 30-inch shielded lead 40.00 4858-L60. Ditto, range pH 0 to 14 43.00

*See H. V. Malmstadt and E. H. Piepmeier, Analytical Chemistry, Vol. 37, No. 1 (January, 1965), p. Si

Thomas Laboratory Electrodes, see 1968 catalog pages 468-473, 488. Thomas Industrial Electrodes, information upon request.

Thomas ARTHUR H. THOMAS COMPANY Scientific Apparatus and Reagents

VINE STREET AT 3RD · P.O. BOX 7 7 9 · PHILADELPHIA, PA. 19105, U.S.A. Circle No. 144 en Readers' Service Card