7ÂÛPUU. -Schoniger LOW PRESSURE, ALL GLASS COMBUSTION APPARATUS For determination of halogens, sulfur, phosphorus, traces of metals, etc., in organic materials • End products free from metal contaminants Rapid, simple and inexpensive . . a simplified technique for catalytic combustion of organic materials in oxygen For the rapid determination of halogens, sulfur, phosphorus, traces of metals, etc., in organic substances by simple combustion in oxygen. No elaborate equipment is required, negligible pressure is produced and the combustion prod- ucts are free from metallic contaminants. The procedure simply converts organic materials into soluble combustion products, which are then analyzed for chlorine, bromine, iodine, fluorine and sulfur by usual inorganic gravimetric or volumetric methods. Consisting of a heavy wall, conical flask of boro- silicate glass, with deep, bell-shape flaring lip and elongated interchangeable ground glass stopper with attached U-shape platinum wire gauze sample carrier, and small, specially cut, unsized low ash paper sheets which serve as holders for the sample. In use, the sample is wrapped and folded in the paper with the narrow tail extending for ignition. Sample is then placed in the platinum carrier and the flask is charged with a small amount of absorb- ing liquid as required for the specific reaction and with free-flowing oxygen. The paper tail is then ignited; the stopper with flaming sample is seated in the flask and flask then inverted at an angle. The catalytic combustion proceeds at high tem- peratures and the combustion products are ab- sorbed in the liquid, which forms a seal around the stopper. After cooling, the inside surfaces of the flask and stopper are thoroughly rinsed. Titrations can then be made directly in the flask. Due to the inherent fragility of glass in the presence of reduced pressure, general safety regula- tions should be followed, such as the use of shield, goggles, etc. Results compare favorably, i.e., within ±0.3%, with conventional combustion or decomposition methods. The method has been used extensively for analysis of the above elements but, because of the low cost, time and space saving features, is finding wide use for other substances which undergo complete combustion. See Wolfgang Schoniger, Mikrochimica Acta, 1955, Heft 1, pp. 123-129; and ibid. 1956, Heft 1-6, pp. 869-876. See also Kenneth D. Fleischer et al, Analytical Chemistry, Vol. 30, No. 1 {Jan., 1958), pp. 152-153, and Ihor Lysyj and John E. Zarembo, Analytical Chemistry, Vol. 30, No. 3 (Mar., 1958), pp. 428-4-30. 6470-E. Combustion Apparatus, Thomas-Schoniger (Schoniger Flask), as above described, 300 ml capacity, for samples up to 1 0 mg. With No. 34/28 standard taper stopper and platinum wire gauze sample carrier weighing approximately 1.5 grams, 100 Paper Sample Holders and directions for use 28.35 6470-G. Ditto, similar to 6470-E but with 500 ml flask, for samples up to 100 mg 29.00 6471-F. Paper Sample Holder, only, an unsized, low ash paper, die-cut to facilitate wrapping, folding and igniting samples. Per 1OO 75 Thorin Indicator, for use with above in determination of sulfates. Per 5 gram bottle 4.95 ARTHUR H. THOMAS COMPANY More and more laboratories rely on Thomas / Laboratory Apparatus and Reagents / V I N E S T . A T 3 R D · PHILADELPHIA Si PA. Circle No. 93 on Readers' Service Card 82 A · ANALYTICAL CHEMISTRY A. H. T. CO. PHllA.. U.S.A.

Upload: hangoc

Post on 12-Feb-2017

213 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ARTHUR H. THOMAS COMPANY

7ÂÛPUU. - S c h o n i g e r LOW PRESSURE, ALL GLASS COMBUSTION APPARATUS

• For determination of halogens, sulfur, phosphorus,

traces of metals, etc., in organic materials

• End products free from metal contaminants

• Rapid, simple and inexpensive

. . a simplified technique for catalytic combustion of organic materials in oxygen

F o r t h e rapid de te rmina t ion of halogens, sulfur, phosphorus , t races of metals , etc. , in organic substances by simple combust ion in oxygen. N o elaborate equ ipment is required, negligible pressure is produced and the combust ion prod­uc ts are free from metall ic con taminan ts .

The procedure simply converts organic materials into soluble combustion products, which are then analyzed for chlorine, bromine, iodine, fluorine and sulfur by usual inorganic gravimetric or volumetric methods.

Consisting of a heavy wall, conical flask of boro-silicate glass, with deep, bell-shape flaring lip and elongated interchangeable ground glass stopper with attached U-shape platinum wire gauze sample carrier, and small, specially cut, unsized low ash paper sheets which serve as holders for the sample.

In use, the sample is wrapped and folded in the paper with the narrow tail extending for ignition. Sample is then placed in the platinum carrier and the flask is charged with a small amount of absorb­ing liquid as required for the specific reaction and

with free-flowing oxygen. The paper tail is then ignited; the stopper with flaming sample is seated in the flask and flask then inverted at an angle. The catalytic combustion proceeds a t high tem­peratures and the combustion products are ab­sorbed in the liquid, which forms a seal around the stopper. After cooling, the inside surfaces of the flask and stopper are thoroughly rinsed. Titrations can then be made directly in the flask.

Due to the inherent fragility of glass in the presence of reduced pressure, general safety regula­tions should be followed, such as the use of shield, goggles, etc.

Results compare favorably, i.e., within ±0 .3%, with conventional combustion or decomposition methods. The method has been used extensively for analysis of the above elements but, because of the low cost, time and space saving features, is finding wide use for other substances which undergo complete combustion.

See Wolfgang Schoniger, Mikrochimica Acta, 1955, Heft 1, pp. 123-129; and ibid. 1956, Heft 1-6, pp. 869-876. See also Kenneth D. Fleischer et al, Analytical Chemistry, Vol. 30, No. 1 {Jan., 1958), pp. 152-153, and Ihor Lysyj and John E. Zarembo, Analytical Chemistry, Vol. 30, No. 3 (Mar., 1958), pp. 428-4-30.

6 4 7 0 - E . Combust ion A p p a r a t u s , Thomas-Schon iger (Schon iger F lask) , as above described, 3 0 0 ml capacity, for samples up to 1 0 mg. Wi th No. 3 4 / 2 8 standard taper stopper and platinum wire gauze sample carrier weighing approx imate ly 1.5 grams, 100 Paper Sample Holders and directions for use 2 8 . 3 5

6 4 7 0 - G . D i t t o , similar to 6470-E but with 5 0 0 ml flask, for samples up to 100 mg 2 9 . 0 0

6471-F. Paper Sample Holder, only, an unsized, low ash paper, die-cut to facilitate wrapping, folding and igniting samples. Per 1OO 75 Thorin Indicator, for use with above in determination of sulfates. Per 5 gram bottle 4.95

ARTHUR H. THOMAS COMPANY More and more laboratories rely on Thomas / Laboratory Apparatus and Reagents

/ V I N E S T . A T 3 R D · P H I L A D E L P H I A S i P A .